CAS Number:
96-37-7
Sum Formula:
C6H12
Molar Mass:
84.2 g/mol
German Synonyms:
Methylcyclopentan
English Synonyms:
Methylcyclopentane
EC Number:
202-503-2
Explosion Group:
IIA (estimated)
Disclaimer: The CLP/GHS classification is not regularly updated in Chemsafe. For up-to-date information, please use the ECHA database. ( https://echa.europa.eu/en/information-on-chemicals )
GHS Hazard and Category:
- Flam. Liq. 2: flammable liquids, category 2
GHS Pictogram:
GHS Signal Word:
Danger
GHS Hazard Statement:
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
Boiling point
1
1950
Matteson, R.
1013.25 hPa
71.8 °C
UTI: 21-1014-14901/0-39
| Line no | Boiling temperature | Pressure |
|---|---|---|
|
|
|
| 1 | 71.8 °C | 1013.25 hPa |
Bibliographic data
| Title | Physical Constants of Hydrocarbons Boiling Below 350 F |
| Author | Matteson, R. |
| Year | 1950 |
| Publisher | American Society For Testing Materials |
| Publisher City | Philadelphia |
| Language | ENGL |
2
1963
Nabert, K.; Schön, G.
1013.25 hPa
72 °C
UTI: 1000-1014-14925/0-39
| Line no | Boiling temperature | Pressure |
|---|---|---|
|
|
|
| 1 | 72 °C | 1013.25 hPa |
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
Density
1
1950
Matteson, R.
1013.25 mbar
15.6 °C
0.754 g/cm3
UTI: 21-1014-14902/0-39
| Line no | Pressure | Temperature | Density |
|---|---|---|---|
|
|
|
|
|
| 1 | 1013.25 mbar | 15.6 °C | 0.754 g/cm3 |
Bibliographic data
| Title | Physical Constants of Hydrocarbons Boiling Below 350 F |
| Author | Matteson, R. |
| Year | 1950 |
| Publisher | American Society For Testing Materials |
| Publisher City | Philadelphia |
| Language | ENGL |
2
1963
Nabert, K.; Schön, G.
1013.25 hPa
20 °C
0.75 g/cm3
UTI: 1000-1014-14926/0-39
| Line no | Density | Temperature | Pressure |
|---|---|---|---|
|
|
|
|
| 1 | 0.75 g/cm3 | 20 °C | 1013.25 hPa |
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
Melting point
1
1950
Matteson, R.
-142.5 °C
UTI: 21-1014-14900/0-39
| Line no | Melting temperature |
|---|---|
|
|
| 1 | -142.5 °C |
Bibliographic data
| Title | Physical Constants of Hydrocarbons Boiling Below 350 F |
| Author | Matteson, R. |
| Year | 1950 |
| Publisher | American Society For Testing Materials |
| Publisher City | Philadelphia |
| Language | ENGL |
2
1963
Nabert, K.; Schön, G.
1013.25 hPa
-142 °C
UTI: 1000-1014-14929/0-39
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
Relative gas density
1
1950
Matteson, R.
2.9053
UTI: 21-1014-14903/0-39
| Line no | Relative gas density |
|---|---|
|
|
| 1 | 2.9053 |
Bibliographic data
| Title | Physical Constants of Hydrocarbons Boiling Below 350 F |
| Author | Matteson, R. |
| Year | 1950 |
| Publisher | American Society For Testing Materials |
| Publisher City | Philadelphia |
| Language | ENGL |
2
1963
Nabert, K.; Schön, G.
2.91
UTI: 1000-1014-14927/0-39
| Line no | Relative gas density |
|---|---|
|
|
| 1 | 2.91 |
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
Solubility in water
1
2009
Physikalisch-Technische Bundesanstalt (PTB)
25 °C
0.043 g/l
UTI: 228-1014-14922/0-39
| Line no | Solubility in water | Temperature |
|---|---|---|
|
|
|
| 1 | 0.043 g/l | 25 °C |
Bibliographic data
| Author | Physikalisch-Technische Bundesanstalt (PTB) |
| Year | 2009 |
| Title | Wasserlöslichkeit |
| Database | PTB |
| Publisher | Datenbank PTB-Lab. 3.43 |
| Language | GERM |
- The oxidizing agent is air with an oxygen content of 20.95 % by volume. In the data base it is usually not specified as mixture component. Exceptions are highlighted.
- Pressure values are absolute, not gauge pressures.
- Impurities can strongly influence characteristic safety data, particulary if the properties of the impurity considerably deviate from the respective properties of the pure substance.
- Safety characteristics are only displayed if evaluated data are available.
- Values can be cited by using the UTI number of the table (Uniform Table Identifier).
- Color Codes: recommended value no recommendation do not use value
Autoignition Temperature
1
1963
Nabert, K.; Schön, G.
315 °C
UTI: 1000-1014-14928/0-39
| Line no | Autoignition Temperature |
|---|---|
|
|
| 1 | 315 °C |
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
2
1941
Sortman, C.W.; Beatty, H.A.; Heron, S.D.
469 °C
UTI: 33-1014-14907/0-39
| Line no | Autoignition Temperature |
|---|---|
|
|
| 1 | 469 °C |
Bibliographic data
| Title | Spontaneous Ignition of Hydrocarbons |
| Author | Sortman, C.W.; Beatty, H.A.; Heron, S.D. |
| Year | 1941 |
| Journal Title | Ind. Eng. Chem. |
| Volume | 33 |
| Issue | 3 |
| Pages | 357-360 |
| Publisher | Ind. Eng. Chem. |
| Language | ENGL |
3
1948
Scott, G.S; Jones, G.W.; Scott, F.E.
329 °C
UTI: 26-1014-14906/0-39
| Line no | Autoignition Temperature |
|---|---|
|
|
| 1 | 329 °C [1] |
| [1] in oxygen |
Bibliographic data
| Title | Determination of Ignition Temperatures of Combustible Liquids and Gases |
| Author | Scott, G.S; Jones, G.W.; Scott, F.E. |
| Year | 1948 |
| Journal Title | Anal. Chem. |
| Volume | 20 |
| Issue | 3 |
| Pages | 238-241 |
| Publisher | Anal. Chem. |
| Language | ENGL |
Flash point
1
1963
Nabert, K.; Schön, G.
< -10 °C
UTI: 1000-1014-14923/0-39
| Line no | Flash point |
|---|---|
|
|
| 1 | < -10 °C |
Bibliographic data
| Author | Nabert, K.; Schön, G. |
| Year | 1963 |
| Title | Sicherheitstechnische Kennzahlen brennbarer Gase und Dämpfe (mit 6. Nachtrag) |
| Publisher | Deutscher Eichverlag |
| Publisher City | Braunschweig |
| Abstract English | Safety values of about 1000 flammable gases and vapors: Explosion limits, ignition temperatures, flash points, explosion pressures. |
| Language | GERM |
Explosion limits
Maximum experimental safe gap
1
Maximum Experimental Safe Gap as a function of temperature and pressure
2023
Physikalisch-Technische Bundesanstalt (PTB), Arbeitsgruppe 3.71
100 kPa
23 °C
0.96 mm
UTI: 4036-1014-60110/20240723-39
| [A] DIN EN ISO/IEC 80079-20-1:2020-09: Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
Bibliographic data
| Author | Physikalisch-Technische Bundesanstalt (PTB), Arbeitsgruppe 3.71 |
| Year | 2023 |
| Title | Sicherheitstechnische Kenngrößen: Messwerte des Labors |
| Database | PTB |
| Publisher | PTB-Lab. 3.71 |
| Language | GERM |
Stoichiometric fraction of combustible substance in mixture with air
1
2005
Physikalisch-Technische Bundesanstalt (PTB)
2.3 Mol%
UTI: 220-1014-14921/0-39
| Line no | Stoichiometric fraction of combustible substance in mixture with air |
|---|---|
|
|
| 1 | 2.3 Mol% |
Bibliographic data
| Author | Physikalisch-Technische Bundesanstalt (PTB) |
| Year | 2005 |
| Title | Berechnete molare stöchiometrische Brenngasanteile in Luft (c_stoech) |
| Database | PTB |
| Publisher | Datenbank PTB-Lab. 3.43 |
| Language | GERM |
No entry in database
- External Links:
- GESTIS
- BAM Dangerous Goods Database